Cut the cable squarely. Using a fixed blade with a prep tool in Fold back the braid. If using tri-shield
good condition, prepare the cable to or quad-shield cables, remove the
5/16” x 1/4” x 1/4” dimensions. Use the additional foil layer and fold back the
edge of the tool if there is no stop. remaining braid.
Ensure the cable is prepared to the Use the guage on the VT tool to check Guide the center conductor and
proper dimensions. the dimension of the center conductor. dielectric into the connector post. Insert
the cable into the connector until the
dielectric is flush within the post.
Here you can see the dielectric is flush Properly seat the connector in the VT Install the connector onto the port and
within the post. tool and fully compress it. tighten to recommended torque.
Part Number Description
EX59 EX® Series universal compression connector for 59 series cable
EX6 EX Series universal compression connector for 6 series cable
S EX59PLUS EX SignalTight® Series universal compression connector for 59 series cable
© EX6PLUS EX SignalTight Series universal compression connector for 6 series cable
Ss VT-300 Universal compression tool, standard body
>
®